Routine Maintenance 
78-545617-01 Rev F 
37 
 
Replacing the Fan 
This section provides instructions for obtaining and replacing the cooling fan unit on 
the QPSK demodulator. 
Notes:  
 
Replace the fan unit only with a genuine replacement fan unit from Cisco. The 
part number for the replacement fan unit is 4016501. The part number for the 
replacement fan kit is 4017943. Contact Cisco to obtain replacement fans. 
 
You must power off the demodulator in order to replace the cooling fan. 
Complete these steps to replace the cooling fan on the back panel of the QPSK 
demodulator.  
1  Power off the QPSK demodulator. 
2  On the back panel of the QPSK demodulator, unplug the fan from the 
connection. 
3  Remove the retaining screws using a Phillips screwdriver and set the non-
functioning fan and screws aside. 
Note: Be sure not to drop or misplace the screws. You will need them to replace 
the fan. 
4  Attach the replacement fan to the back panel using the same screws you 
removed previously making sure that you orient the fan so that the airflow 
blows outward. 
Note: Be sure to use a torque of approximately 4-6 in.-lb. 
5  Plug the replacement fan into the power connection provided on the back panel. 
6  Power on the QPSK demodulator. 
7  Verify that the replacement fan is operating correctly. If the replacement fan does 
not operate correctly, contact Cisco Services for assistance.