Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide

Page of 178
 
 
Monitor Setup Options 
4004834 Rev D 
91 
 
Displaying Alarm Status 
Follow these steps to display the list of active alarms. 
1  Press OPTIONS. The Alarm Status screen appears. 
Alarm at 11:51:03
Input1 loss of signal
 
Notes: 
 
Each alarm description appears for approximately 1 second before displaying 
the next alarm. If no alarms are active, a No Active Alarms message appears. 
 
See Troubleshooting Alarm Messages for detailed descriptions of alarms. 
2  Press ENTER. The default screen appears. 
 
Viewing the Session Count 
The Session Count screen displays the count of all active sessions for the selected RF 
output. Follow these steps to view the total number of active sessions. 
1  Press OPTIONS twice. The Session Count screen appears. 
CH1 Session Count
10
 
Note: The session count for the GoQAM will differ from the session count on the 
DNCS if the GoQAM does not find needed MPEG programs within MPEG 
Program Specific Information (PSI). By design, the GoQAM responds positively 
to a session setup request even if the requested MPEG program is not present on 
the input transport stream. 
2  Press RF SEL to view the session count for each channel (CH1 or CH2). 
3  Press ENTER to return to the default screen. 
 
Viewing the Program Count 
The Program Count screen displays the encrypted programs currently running on 
the selected RF output. Follow these steps to view the program count for an RF 
module. 
1  Press OPTIONS three times. The Program Count screen appears. 
CH1 Program Count
5
 
2  Press RF SEL to view the program count for each channel (CH1 or CH2). 
3  Press ENTER to return to the default screen.