Cisco Model GS7000 4-Port Node 1 GHz with 65 86 Split Installation Guide

Page of 192
 
 
Pedestal or Wall Mounting the Node 
 
41 
 
and set the bolts and strand clamps aside. 
3  Position the 1.2 GHz GS7000 Node horizontally in the enclosure and allow for 
free flow of air around it. Inadequate airflow could cause the node to exceed 
thermal parameters. Line up the bolt holes on the bottom of the housing with the 
mounting holes on the pedestal bracket provided by the pedestal manufacturer. 
 
 
 
Important: The node housing must be mounted horizontally, as shown, to 
ensure proper airflow over the housing cooling fins. Do NOT mount the node 
housing vertically. 
4  Secure the node housing to the pedestal bracket using the strand clamp bracket 
bolts you removed in step 2. Insert the bolts into the mounting holes. Use the 
strand clamps as spacers if necessary. Torque the bolts from 8 ft-lb to 10 ft-lb 
(10.8 Nm to 13.6 Nm). 
5  Connect the coaxial cable to the pin connector according to connector 
manufacturer’s specifications. 
6  Ground the equipment in accordance with local codes and regulations. 
7  Continue to Fiber Optic Cable Installation (on page 42) and RF Cable 
Installation (on page 50).