Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide
Configuring the Transponder Using the SA-HMS-FIBERNODEGS7000 MIB
4037424 Rev A
23
Component
Description
saFnOpticalReceiverHiPwrLimit
(OID 1.3.6.1.4.1.1429.1.6.5.2.4.1.3)
Sets the maximum threshold level for input
signal to the A/B switch in mW. The default is
2.00 and the range is 0.25-2.40.
signal to the A/B switch in mW. The default is
2.00 and the range is 0.25-2.40.
Notes:
This parameter is not implemented within
the transponder in versions earlier than 4.1.0.
the transponder in versions earlier than 4.1.0.
When the saFnOpticalReceiverHiPwrLimit
(OID 1.3.6.1.4.1.1429.1.6.5.2.4.1.3) is set, the
HIHI alarm limit for the
fnOpticalReceiverPower (OID
1.3.6.1.4.1.5591.1.5.5.1.2) is also set.
(OID 1.3.6.1.4.1.1429.1.6.5.2.4.1.3) is set, the
HIHI alarm limit for the
fnOpticalReceiverPower (OID
1.3.6.1.4.1.5591.1.5.5.1.2) is also set.
When the HIHI alarm limit is set for the
fnOpticalReceiverPower (OID
1.3.6.1.4.1.5591.1.5.5.1.2), the
saFnOpticalReceiverHiPwrLimit (OID
1.3.6.1.4.1.1.429.1.6.5.2.4.1.3) is also set.
fnOpticalReceiverPower (OID
1.3.6.1.4.1.5591.1.5.5.1.2), the
saFnOpticalReceiverHiPwrLimit (OID
1.3.6.1.4.1.1.429.1.6.5.2.4.1.3) is also set.
Although the
saFnOpticalReceiverHiPwrLimit displayed
precision is to the hundredths, the actual
precision is only to the tenth.
saFnOpticalReceiverHiPwrLimit displayed
precision is to the hundredths, the actual
precision is only to the tenth.
The precision of the fnOpticalReceiverPower
is in tenths, so when the value is set for the
saFnOpticalReceiverHiPwrLimit, the HIHI
alarm limit for the fnOpticalReceiverPower
will be truncated to display tenths.
is in tenths, so when the value is set for the
saFnOpticalReceiverHiPwrLimit, the HIHI
alarm limit for the fnOpticalReceiverPower
will be truncated to display tenths.
saFnReturnLaserSlot
(OID 1.3.6.1.4.1.1429.1.6.5.2.2.1.2)
(OID 1.3.6.1.4.1.1429.1.6.5.2.2.1.2)
Configures the transmitter slots to indicate if a
transmitter is installed or not installed. Set the
active slots to Mount and the slots, if any, that do
not have an installed transmitter to Unmount.
transmitter is installed or not installed. Set the
active slots to Mount and the slots, if any, that do
not have an installed transmitter to Unmount.