Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 76
 
Chapter 2    Installation 
 
12 
4024769 Rev A
Installing the SM/LCM 
Overview 
You must perform the following steps to install the SM/LCM in the Model GS7000 
Node. 
1  Open the node housing. 
2  Install the SM/LCM into the housing lid. 
3  Close the node housing. 
The following sections describe each of these steps in detail. 
 
Opening the Housing 
Open the housing as follows. 
1  Remove the bolts securing the lid to the base. 
2  Carefully open the lid to allow access to the inside of the housing. 
3  Inspect gaskets on the cover flange and on the test port plugs. 
4  Replace any gaskets showing signs of wear (cracked, twisted, pinched, or dry) 
with new, silicon-lubricated gaskets. 
 
Installing the Module 
Complete the following steps to install the SM/LCM into the node lid. 
1  Inspect the pins on the electrical connector on the rear panel of the SM/LCM 
module prior to inserting the module in the node. 
 
 
CAUTION: 
Make sure that all pins on the connector are straight and also level, i.e., they 
are all at the same height.  If not, damage may result to the connector pins 
upon installation, installation may be impeded, or the module may not 
function properly. 
 
Note:  If the pins are not straight and level, the module should be returned to the 
factory.  Refer to Chapter 5, Customer Support Information, for information on 
obtaining support and returning products.