Cisco Headend System Release 2.7 User Guide
Chapter 2 Monitoring SDV Alarms
50
4019781 Rev B
SDV Server Trap 501 (1F5 Hex)
Alarm Summary:
SDV Forced Protection Switch Failure
Description:
This alarm occurs when the SDV server cannot perform a protection switch to its
partner SDV server.
partner SDV server.
Severity:
Major
Service Impact:
This is a redundancy failure that impacts the ability to use an SDV server as a
backup.
backup.
Check and Correct:
Possible Cause
Check and Correct Instructions
Communications problem.
Investigate and troubleshoot all SDV
System Communications alarms.
System Communications alarms.
Partner SDV server is down.
1
Investigate all SDV server alarms and
errors that may have occurred around
the time of the SDV server failure,
particularly SDV Server Process alarms
before the time of the failure.
errors that may have occurred around
the time of the SDV server failure,
particularly SDV Server Process alarms
before the time of the failure.
2
Call Cisco Services immediately for
further assistance.
further assistance.