Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 72
 
 Local 
Control 
Module 
Configuration Procedure 
4022871 Rev C 
19 
 
Menu Item  Configuration Parameter  Description/Values 
RX & TX Config 
RX1 
RX2 
RX3 
RX4 
TX1 
TX2 
TX3 
TX4 
 
Description:  Read/Write configurable 
parameter.  Specifies whether receivers 1 
through 4 and transmitters 1 through 4 are 
installed in the node. 
 
Values:  Present, Absent 
2 PS 
Config 
AC1 
AC2 
PS1 
PS2 
 
Description:  Read/Write configuration 
parameter.  Specifies whether AC input power 1 
and/or 2, and power supplies 1 and 2 are 
installed in the node. 
 
Values:  Present, Absent 
3 RX 
Tresholds 
RX1 Min 
RX2 Min 
RX3 Min 
RX4 Min 
RX1 Max 
RX2 Max 
RX3 Max 
RX4 Max 
 
Description:  Read/Write configuration 
parameter.  Specifies the switching levels for the 
two AB switches.  Enter minimum and 
maximum power thresholds for receivers 1 
through 4 switching levels. 
 
Values:  #.# mW 
Defaults:  0.5 mW min., 2.0 mW max. 
4 TX 
Thresholds 
TX1 Min 
TX2 Min 
TX3 Min 
TX4 Min 
TX1 Max 
TX2 Max 
TX3 Max 
TX4 Max 
 
Description:  Read/Write configuration 
parameter.  Specifies the minimum and 
maximum power thresholds for transmitters 1 
through 4 switching levels. 
 
Values:  #.# mW 
Defaults:  0.5 mW min., 2.3 mW max.