Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide

Page of 128
 
 
 
Replace the Fuses 
 
4001444 Rev C 
89 
 
Replace the Fuses 
Each Netcrypt Bulk Encryptor contains two power fuses. This section describes how 
to replace the fuses with spares that you should have on hand. 
 
Before You Begin 
 
 
CAUTION: 
To minimize the disruption of services, we recommend keeping two spare 
fuses for each Netcrypt Bulk Encryptor in your system. 
To replace the fuses, you must have the following: 
 
Two 4.0 A, SLO BLO 250 V fuses (part number 188106) 
 
A small, flat-blade screwdriver or similar tool to pry the fuse holder from the 
back panel of the Netcrypt Bulk Encryptor 
 
Replacing the Fuses 
 
 
WARNING: 
Avoid electric shock. Disconnect the power cord on this product before you 
remove the fuses and only use fuses that have the correct type and rating. 
To replace the SLO BLO 250 V fuses, follow these steps. 
1  Power down the Netcrypt Bulk Encryptor and unplug the power cord from the 
back panel. 
2  Locate the fuse holder on the left side of the back panel of your Netcrypt Bulk 
Encryptor.  
 
3  Use a small, flat-blade screwdriver to pry the fuse holder from the back panel of 
the Netcrypt Bulk Encryptor. 
4  Remove and discard both blown fuses, and replace them with new fuses.  
5  Insert the fuse holder into the back panel and press firmly until it snaps in place. 
6  Replace the power cord and power on the Netcrypt Bulk Encryptor. 
7  If necessary, order additional fuses to ensure that you have spares readily 
available. See Customer Information (on page 111) for the telephone number of a 
customer service center in your area.