Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide

Page of 128
 
Chapter 1    Introducing the Netcrypt Bulk Encryptor 
 
 
 
12 
4001444 Rev C 
Using GbE Transport Clouds and Splitter Clouds for VOD Applications 
It is possible to more tightly control the use of Netcrypt Bulk Encryptors by 
connecting sources to the GbE Transport Networks as shown in the example below. 
In this case, the GbE port IP addresses of the VOD pumps are entered into the DNCS 
when connecting pump ports to GbE Transport Network ports. 
In this case, the DNCS will use Netcrypt Bulk Encryptor 3 only for streams coming 
from VODSource3. Similarly it will use Netcrypt Bulk Encryptor1 for streams 
coming from VODSource1 and so on. 
The problem with this method is that not all VOD servers specify their selected 
source ports to the DNCS when a VOD session is set up. If a VOD server fails to 
specify the source IP address for a stream, the ambiguity will not be resolved and the 
DNCS will respond to the VOD server with the IP address of any Netcrypt Bulk 
Encryptor it chooses given the connectivity that has been specified.