Chapter 1    Introducing the Netcrypt Bulk Encryptor 
 
 
 
22 
4001444 Rev C 
Front Panel Overview 
Front Panel Diagram 
This illustration shows the front panel components of the Netcrypt Bulk Encryptor. 
The following table describes the labeled components. 
 
Front Panel Indicators 
The following table provides front panel alarm and component descriptions that 
correspond to each number in the preceding labeled diagram of each type of 
Netcrypt Bulk Encryptor. 
Item 
Indicator 
Description 
POWER (green) 
Turns solid green when the unit is receiving power 
RUN/LOAD (green) 
 
Turns solid green during normal run mode.  
 
Blinks green during code downloads. 
RESET (yellow)  
Turns yellow when the Netcrypt Bulk Encryptor is reset 
from the DNCS or when it is reset from the back panel 
(by turning power off and on again). 
MINOR ALARM 
(yellow) 
Turns yellow for a minor alarm condition. Minor alarms 
indicate a less critical error condition. The Netcrypt Bulk 
Encryptor may continue to operate with some loss of 
functionality. The LED turns off when all minor alarms 
have cleared. 
MAJOR ALARM 
(red) 
Turns red for a major alarm condition. Major alarms 
occur for hardware or software conditions that indicate 
a serious disruption of service or the malfunctioning or 
failure of important circuits. The LED turns off when all 
major alarms have cleared.