Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide
Add Table-Based QAM Information to the DNCS
4012215 Rev B
51
Add Table-Based QAM Information to the DNCS
This section provides instructions for completing the following tasks that are
required in order to add TB-QAM modulator information to the DNCS. The DNCS
uses this information to direct program streams to a TB-QAM that a NOBE feeds.
1 Add a TB-QAM modulator element to the DNCS.
2 Enter the RF parameters for a TB-QAM modulator.
3 Enter the mapping table for a TB-QAM modulator.
required in order to add TB-QAM modulator information to the DNCS. The DNCS
uses this information to direct program streams to a TB-QAM that a NOBE feeds.
1 Add a TB-QAM modulator element to the DNCS.
2 Enter the RF parameters for a TB-QAM modulator.
3 Enter the mapping table for a TB-QAM modulator.
Although adding TB-QAM information to the DNCS is very similar to provisioning
elements on the DNCS, the results are different: Unlike most DNCS elements, the
DNCS does not control TB-QAMs. Instead, the DNCS uses the information you have
entered about TB-QAMs to direct program streams to TB-QAMs when required.
elements on the DNCS, the results are different: Unlike most DNCS elements, the
DNCS does not control TB-QAMs. Instead, the DNCS uses the information you have
entered about TB-QAMs to direct program streams to TB-QAMs when required.
Adding a TB-QAM Modulator Element to the DNCS
Follow these instructions to enter data in the fields of the Add Table-Based QAMs
List window:
List window:
Note: Adding a TB-QAM modulator element to the DNCS does not allow the DNCS
to provision or communicate with the TB-QAMs you add. Instead, the DNCS uses
the information you enter to direct program streams to TB-QAM modulators when
required. Each TSR has a TSR ID that uniquely identifies it throughout the system
and as is passes blindly through the NOBE.
1 From the DNCS tab on the DNCS Administrative Console, click Network
to provision or communicate with the TB-QAMs you add. Instead, the DNCS uses
the information you enter to direct program streams to TB-QAM modulators when
required. Each TSR has a TSR ID that uniquely identifies it throughout the system
and as is passes blindly through the NOBE.
1 From the DNCS tab on the DNCS Administrative Console, click Network
Element Provisioning. The Network Element Provisioning tab comes to the
forefront.
forefront.
2 Click Table-Based QAM. The Table-Based QAMs List window opens.
3 Click Add. The Add Table-Based QAM window opens.
3 Click Add. The Add Table-Based QAM window opens.