Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide

Page of 130
 
Chapter 3    Provisioning the NOBE and Associated Devices 
 
 
 
58 
4012215 Rev B 
4  Enter the following information in the fields of the Basic Parameters tab:  
 
GbE Transport Name – A name for the transport network 
Note: You can use up to 20 alphanumeric characters. We recommend that 
you establish a naming scheme that allows you to easily identify this 
transport network and where it resides. For example, a name of 
CFhub1GTN43 could represent a GbE transport network that connects to 
Hub 1 and is connected to a NOBE by a device whose IP address ends in 43. 
 
IP Address – The IP address of the transport device, such as a switch or 
router, that is physically connected to this NOBE. 
Note: This address is not used by the DNCS and simply provides a 
convenient place to save and retrieve this information should you wish to 
ping or telnet to the router or switch for monitoring or diagnostic purposes.  
5  Click Apply. The DNCS saves this data and makes the Connectivity tab available 
for you to select. 
6  Click the Connectivity tab, and re-size the window to view all of the tab. 
7  Click Create Port. The Port Number Prompt window opens. 
8  Enter a number to identify the input port on the GbE transport network device 
that will receive data from a NOBE or other source and click OK. The Port 
Number Prompt window closes, and a box representing the port appears in the 
Input Port column. 
9  For each additional input port on the GbE transport network device, repeat steps 
7 and 8 to create these input ports. 
10  Click Create Port. The Port Number Prompt window opens. 
11  Click Output. The Output port type option turns on. 
12  Enter the number to identify the output port on the GbE transport network 
device that will be used to forward data to other devices in the transport 
network, and click OK. The Port Number Prompt window closes, and a box 
representing the port appears in the Output Port column. 
13  For each additional output port on the GbE transport network device, repeat 
steps 10 through 12 to create these output ports.