Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 16
 
10 
 
OL-29941-01 
 
Upgrading the RF Split in the GS7000 Node 
 
15  Install the RF module into the test GS7000 Node housing. 
16  Attach a network analyzer or stealth meter to output port 1 of the RF Amp 
module. 
17  Referring to the Signal Path Table that you completed at the end of Verifying 
Signal Paths (on page 4), connect the cable adapter (part number GS7K-SPLKT-
CBL) from the RF test source to the input receiver port on the launch amplifier 
that corresponds to output port 1. 
 
 
 
WARNING: 
Potentially lethal voltages may be present inside the node. Follow 
appropriate safety precautions and practices to avoid electric shock when 
working inside the node.
 
 
18  Complete the adjustment procedure described in Forward Band Low End Peak 
Adjustment (on page 11) for output port 1. 
19  Repeat this adjustment procedure for each of the remaining output ports to fully 
verify correct operation.