Reset the OUI 
4020695 Rev C 
227 
 
Resetting the Null OUI 
Follow these instructions for an example of when to reset the null OUI, as well as for 
instructions on running the updateOUI utility with the -rz option, which resets the 
null OUI. 
1  If necessary, open an xterm window on the DNCS. 
2  Type updateOUI  -i and then press Enter. The xterm window updates to show 
the number of MAC addresses and OUIs associated with the DHCTs in the 
database. 
> updateOUI -i 
-------------------------------------------------------------------------------------------------- 
Mar 23, 8:07:23 - updateOUI Started. 
updateOUI Options: -i (Information only);  
SAFE mode - No database modifications will be done! 
Total DHCTs (hct_profile rows) in the database...........   1519 
-------------------------------------------------------------------------------------------------- 
<---------MACaddr Counts--------->  <-----------OUI Counts-----------> 
 02:DE  01:A6  40:7B  0A:73  other   02:DE  01:A6  40:7B  0A:73  other   Total 
  ------     ------     ------    ------    ------    ------     ------    ------    ------    ------  ------ 
      64       116       551      787      1        1510          8         0         0            1      1519 
-------------------------------------------------------------------------------------------------- 
'other':           Pace     Panason     Pioneer   SciAtl     Null     UnKnown 
-value-:         50:94          80:45        E0:36     0F:21     --:--            ??:?? 
OUI count:         0                  0               0             0          0                    1 
Mar 23, 8:07:23 - updateOUI Ended. 
-------------------------------------------------------------------------------------------------------- 
3  Check the number of DHCTs that have the null OUI.   
Note:  If this number is more than what you consider to be reasonable, then these 
DHCTs should be reset to the first three octets of the DHCT MAC address. Then, 
you should run the updateOUI utility in the forward direction to set the OUI 