Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Installation Guide

Page of 113
4-20 
Operation Using LCI 
78-715193-01 Rev C 
Checking bdr Receive Processor Alarms 
Introduction 
Using LCI, you can check the alarm status of various parameters.  Alarms that you 
can check are listed below. 
 
Alarm 
Parameter 
Alarm 
Condition 
Alarm 
Indication  Possible Cause or Remedy 
Module 1.8 
Voltage 
1.8 Voltage fault  Alarm 
1.8 Voltage level internal to the 
receiver too high or low. 
Module 3.3 
Voltage 
3.3 Voltage fault  Alarm 
3.3 Voltage level internal to the 
receiver too high or low. 
Module 
Temperature 
Temperature too 
high or low 
Alarm 
Module temperature too high 
or low. 
Summary Status  Normal or Alarm  Alarm 
Any alarm in the device. 
Communication 
Status 
Communication 
fault 
Alarm 
Communication alarm. 
Receiver 1 Status  Receiver 1 not 
present  
Alarm 
Receiver 1 not installed. 
Receiver 2 Status  Receiver 2 not 
present  
Alarm 
Receiver 2 not installed. 
Receiver 1 Loss 
of Signal Status 
Receiver 1 loss of 
signal 
Alarm 
Check fiber line and data into 
receiver 1. 
Receiver 2 Loss 
of Signal Status 
Receiver 2 loss of 
signal 
Alarm 
Check fiber line and data into 
receiver 2. 
Framing Status 
The signal 
cannot be framed 
Alarm 
Check fiber connection path 
and bdr transmitter. 
FPGA Status 
FPGA fault 
Alarm 
Indicates the internal FPGA has 
stopped working.  Unit needs 
repair. 
Receiver 
Communication 
Status 
Cannot 
communicate 
with the receiver 
Alarm 
Cannot communicate with the 
receivers.  Reseat or replace the 
receivers. 
Recovered Clock  Internal clock 
generator fault 
Alarm 
Unit needs repair. 
Power Supply 
Status 
Power supply 
fault 
Alarm 
Chassis power supply.  Make 
sure power supply is fully 
seated. Check power cord.