Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Installation Guide

Page of 113
5-4 
Maintenance and Troubleshooting 
78-715193-01 Rev C 
Troubleshooting Alarm Conditions 
Alarm Conditions
 
If the red ALARM indicator is illuminated or is blinking, check the ICIM or LCI to 
determine the cause of the alarm.  
Alarm  
Alarm Condition 
Indicati
on 
Possible Cause 
Rcv1Pres 
Receiver sub-module 
1 not present  
Fault 
Receiver 1 not present.  
Rcv2Pres 
Receiver sub-module 
2 not present  
Fault 
Receiver 2 not present.  
Rcv1_LOS 
Receiver sub-module 
1 loss of signal 
Fault 
Check fiber line and data into 
receiver sub-module 1. 
Rcv2_LOS 
Receiver sub-module 
2 loss of signal 
Fault 
Check fiber line and data into 
receiver sub-module 2. 
Framing 
The signal cannot be 
framed 
Fault 
Check fiber connection path, and 
bdr transmitter. 
Power_In 
Power supply 
indicates a fault 
Fault 
Check power cord.  Make sure 
power supply is fully seated. 
+1_8VInt 
Internal 1.8 Voltage 
Fault 
Check power supply module(s). 
+3_3VInt 
Internal 3.3 Voltage 
Fault 
Check power supply module(s). 
ProcTemp 
Module Temperature  Fault 
Check fan tray operation. 
FPGA 
FPGA operation 
Fault 
Indicates the internal FPGA has 
stopped working.  Unit needs 
repair. 
OSM_Comm  Cannot communicate 
with the optical 
receiver sub-module 
Fault 
Cannot communicate with the 
receiver.  Reseat or replace the 
receiver sub-module. 
APDBias1 
APD1 bias incorrect 
Fault 
Re-seat receiver sub-module 1. 
Replace if necessary. 
APDBias2 
APD2 bias incorrect 
Fault 
Re-seat receiver sub-module 2. 
Replace if necessary. 
Clock100 
Internal clock 
generator 
Fault 
Unit needs repair.