Configuring the bdr Transmit Processor
Introduction
Using the LCI software, you can configure the parameters listed below.
Configurable Parameters
Configurable parameters for the Prisma II bdr Transmit Processor are listed below.
Parameter
Function
Values
Default
Redundant
Mode
The typical number of
transmitters to be used in
this unit. No, if there is
typically 1 transmitter.
Yes, if there are typically
2 transmitters. If set to
No, no alarm is generated
when the second
transmitter is removed.
Yes or No
Yes
RF Drive
Stream A
Amount of attenuation on
input A
0 dB to 10.0 dB in 0.1 dB
increments
0.0 dB
RF Drive
Stream B
Amount of attenuation on
input B
0 dB to 10.0 dB in 0.1 dB
increments
0.0 dB
Clock Source Master, Slave, or
Independent
Indpend - Transmitter
generates the clock
signal but does not send
it outside the module.
Master - Transmitter
generates it’s own clock
signal and sends it out.
Slave - Uses the clock
input supplied from the
backplane, typically
from another transmitter
in Master mode. If the
clock is not present clock
alarms are generated.
Independ
Noise
Suppression
Controls noise
suppression
On or Off
On
Transmitter 1
Enable
Enables or disables
transmitter 1 operation
Enable/Disable
Enable
Transmitter 2
Enable
Enables or disables
transmitter 2 operation
Enable/Disable
Enable