Operation Using the LCI Software 
4-19 
Configuring the bdr Transmit Processor  
Introduction 
Using the LCI software, you can configure the parameters listed below.  
Configurable Parameters  
Configurable parameters for the Prisma II bdr Transmit Processor are listed below. 
 
Parameter 
Function 
Values 
Default 
Redundant 
Mode 
The typical number of 
transmitters to be used in 
this unit.  No, if there is 
typically 1 transmitter. 
Yes, if there are typically 
2 transmitters.  If set to 
No, no alarm is generated 
when the second 
transmitter is removed. 
Yes or No 
Yes 
RF Drive 
Stream A 
Amount of attenuation on 
input A 
0 dB to 10.0 dB in 0.1 dB 
increments 
0.0 dB  
RF Drive 
Stream B 
Amount of attenuation on 
input B 
0 dB to 10.0 dB in 0.1 dB 
increments 
0.0 dB  
Clock Source  Master, Slave, or 
Independent 
Indpend - Transmitter 
generates the clock 
signal but does not send 
it outside the module. 
Master - Transmitter 
generates it’s own clock 
signal and sends it out. 
Slave - Uses the clock 
input supplied from the 
backplane, typically 
from another transmitter 
in Master mode.  If the 
clock is not present clock 
alarms are generated. 
Independ 
Noise 
Suppression 
Controls noise 
suppression 
On or Off 
On 
Transmitter 1 
Enable  
Enables or disables 
transmitter 1 operation 
Enable/Disable 
Enable 
Transmitter 2 
Enable  
Enables or disables 
transmitter 2 operation 
Enable/Disable 
Enable