Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Installation Guide

Page of 114
5-4 
Maintenance and Troubleshooting 
78-715192-01 Rev C 
Troubleshooting Alarm Conditions 
ICIM Alarm Conditions
 
If the red ALARM indicator is illuminated or is blinking, check the ICIM to 
determine the cause of the alarm.  Blinking = minor alarm, steady illumination = 
major alarm. 
Alarm  
Alarm Condition 
Indication  Possible Cause 
FPGA 
Indicates that the FPGA 
can be read from and 
written to 
Fault 
Hardware failure. 
OSM_Comm 
Gets set when it is not 
possible to read and 
write the to EEPROM 
in an installed OSM 
(Transmitter  sub-
module). 
Fault 
Ensure transmitter sub-module 
is fully seated.  Remove and 
reinstall sub-module.   
Power_In 
Status of +24V and –5V 
power inputs. 
Fault 
Check power supplies.  Make 
sure the power supply module 
is fully seated in chassis. 
Clock100 
Alarms when the 100 
MHz clock does not 
lock on to the 1 MHz 
reference. 
Fault 
Ensure processor Clk_Src has 
not been accidentally set to 
Slave.  If in Slave mode make 
sure there is a valid 1 MHz 
reference present. 
Clock125 
Alarm when 125 MHz 
clock will not lock on 
100 MHz clock 
Fault 
Hardware failure. 
Lsm1Pres 
Transmitter sub-
module 1 is missing.   
Fault 
Ensure transmitter sub-module 
1 is installed and fully seated. 
Lsm1EOL 
Laser 1 is near end of 
life.  
Fault 
Time to replace transmitter 
sub-module 1. 
Lsm1Temp 
Laser 1 temperature is 
out of spec.   
Fault 
Ensure transmitter sub-module 
1 is within temperature specs 
and laser has had a chance to 
stabilize.  Check chassis fans. 
Lsm2Pres 
Transmitter sub-
module 2 is missing.   
Fault 
Ensure transmitter sub-module 
2 is installed and fully seated.   
Lsm2EOL 
Laser 2 is near end of 
life.  
Fault 
Time to replace transmitter 
sub-module 2. 
Lsm2Temp 
Laser 2 temperature is 
out of spec.   
Fault 
Ensure transmitter sub-module 
2 is within temperature specs 
and laser has had a chance to 
stabilize.  Check chassis fans.