Cisco Headend System Release 2.7 Installation Guide

Page of 142
 
 
 
Verify SR i4.2.2 
 
4036631 Rev B 
91 
 
Verify SR i4.2.2 
Verifying the System Upgrade 
Complete these steps to verify a successful upgrade to SR i4.2.2. 
1  Examine the dncsLog file in the /var/log directory to see if there are VASP entry 
errors. 
 
If yes, complete these steps to rebuild the VASP entries. 
a  Open the DNCS Administrative Console, select the System Provisioning 
tab, and then click ATM PVC. The ATM PVC Map List window appears. 
b  Record all of the information from the ATM PVC Map List window on a 
piece of paper. 
c  Delete all of the entries from the ATM PVC Map List window. 
d  Re-enter each entry from the recorded information. 
 
If no, go to step 2. 
2  Type cd  /dvs/dncs/Utilities/doctor and press Enter
3  Type doctor  -vn and press Enter. This command runs the Doctor Report 
generates. Review the Doctor Report to ensure that communications exists 
between all DBDS elements. 
Important:  It is normal for Rovi Corporation sites to report errors on 
Application Server checks. 
4  Type df  -k and then press Enter to verify that you are using no more than 85 
percent of the partition capacity of each disk. 
Important:  If any disk partition lists a capacity greater than 85 percent, contact 
Cisco Services at 1-866-787-3866 before proceeding. 
5  Complete these steps to perform a slow and fast boot on a test DHCT with a 
working return path (2-way mode): 
a  Boot a DHCT. 
Note:  Do not press the power button. 
b  Access the Power On Self Test and Boot Status Diagnostic Screen on the 
DHCT and verify that all parameters, except UNcfg, display Ready.   
Note:  UNcfg displays Broadcast
c  Wait 5 minutes. 
d  Press the power button on the DHCT. The power to the DHCT is turned on. 
e  Access the Power On Self Test and Boot Status Diagnostic Screen on the 
DHCT and verify that all parameters, including UNcfg, display Ready