Cisco Headend System Release 2.7 Installation Guide

Page of 142
 
Chapter 1    SR i4.2.2 DVD Pre-Upgrade Procedures 
 
 
 
10 
4036631 Rev B 
Examine Disks and Mirrored Devices 
Examine the status of the mirrored disk drives on the Sun Fire V445, V880 or V890 
DNCS prior to the SR i4.2.2 upgrade. All the disk mirroring functions must be 
working normally before proceeding with the upgrade. 
 
CAUTION: 
If the disk mirroring functions of the DNCS are not working properly before the 
upgrade, you may not be able to easily recover from a failed upgrade. 
 
Examining Disks and Mirrored Devices 
Follow these instructions to examine the status of the mirrored drives on your 
DNCS. This procedure should take only a few minutes to complete. 
1  If necessary, open two xterm windows on the DNCS. 
2  In one of the windows, type metastat  |  more and then press Enter. The system 
displays the status of all of the metadevices on the DNCS. 
Note:  Press the Spacebar, if necessary, to page through all of the output. 
3  Do all metadevices display a state of OK
 
If yes, go to step 4. 
 
If no, call Cisco Services for help in resolving these issues with the 
metadevices. 
4  Follow these instructions to log on to one of the xterm windows as root user. 
a  Type su - and press Enter. The password prompt appears. 
b  Type the root password and press Enter
5  In the root xterm window, type format  </dev/null and then press Enter to 
confirm that all disks are present and readable. 
Example:  You should see output similar to the following example, that assumes 
you have a 6-disk, Sun Fire V880: 
AVAILABLE DISK SELECTIONS:
 
       0. c1t0d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
 
          
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0108977d1,0
 
1. c1t1d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
 
.
 
..
 
11. c2t5d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>
 
/pci@9,600000/pci@1/SUNW,qlc@4/fp@0,0/ssd@w2200000c5056c543
,0