Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide
Chapter 4 Initializing the TED FX Server
16
736138 Rev F
Stop System Components
Important: System components must be stopped before you install the TED files.
The TED files are a group of files that install and execute the encryption and
The TED files are a group of files that install and execute the encryption and
decryption software. Use the procedures in this section to stop system components
in the proper order. Failing to stop system components in the order described in this
section may cause you to encounter difficulties during the installation.
Introduction
Before continuing with the installation process, follow the instructions in this section
to stop the Application Server for your system and the DNCS/ISDS.
Stopping the Application Server
This section provides procedures for stopping a SARA Server, an Aptiv Application
Server, if necessary, or the Time Warner Mystro Application Server (MDN), if
necessary. Choose the procedure that pertains to your system.
Stopping the Application Server at SARA Sites
1 Press the middle mouse button on the Application Server and select App Serv
1 Press the middle mouse button on the Application Server and select App Serv
Stop.
2 From an xterm window on the Application Server, type appControl and then
press Enter. The Applications Control window appears.
3 Type 2 (for Startup/Shutdown Single Element Group), and then press Enter. The
system displays all Application Server processes.
Note: The system updates the display periodically, or you can press Enter to
Note: The system updates the display periodically, or you can press Enter to
force an update.
4 When the Curr Stt (Current State) field of the Applications Control window
indicates that all of the Application Server processes have stopped, follow the
on-screen instructions to close the Applications Control window.
5 Type appKill and then press Enter. The appInitd process stops.
Stopping the Time Warner Mystro Application Server
If the site you are upgrading uses the Time Warner Mystro application server
If the site you are upgrading uses the Time Warner Mystro application server
(MDN), refer to the documents provided by Mystro to shut down the Mystro
application server.
Stopping the Aptiv Application Server
If your site uses the Aptiv application server, refer to the documents provided by
If your site uses the Aptiv application server, refer to the documents provided by
Aptiv to shut down the Aptiv application server.