Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide

Page of 84
 
 
 
Verify Disk Drive Status 
 
4005697 Rev B 
51 
 
Verify Disk Drive Status 
Follow these instructions to determine whether one or more metadevices have failed 
on the system. 
1  If necessary, open an xterm window on the DNCS. 
2  Type the following command and press Enter
metastat
 
Result:  Lengthy output, similar to the following, appears. As you examine the 
output, notice devices that have a State of Needs maintenance
d510: Mirror
 
    Submirror 0: d410
 
      State: Okay
 
    Submirror 1: d710
 
      State: Needs maintenance
 
    Pass: 1
 
    Read option: roundrobin (default)
 
    Write option: parallel (default)
 
    Size: 50340672 blocks (24 GB)
 
d410: Submirror of d510
 
    State: Okay
 
    Size: 50340672 blocks (24 GB)
 
    Stripe 0:
 
        Device     Start Block  Dbase        State Reloc Hot Spare
 
        c1t0d0s5          0     No            Okay   Yes
 
d710: Submirror of d510
 
    State: Needs maintenance
 
    Invoke: metareplace d510 c1t4d0s5 <new device>
 
    Size: 50340672 blocks (24 GB)
 
    Stripe 0:
 
        Device     Start Block  Dbase        State Reloc Hot Spare
 
        c1t4d0s5          0     No     Maintenance   Yes
 
d507: Mirror
 
    Submirror 0: d407
 
      State: Okay
 
    Submirror 1: d707
 
      State: Needs maintenance
 
    Pass: 1
 
    Read option: roundrobin (default)
 
    Write option: parallel (default)
 
    Size: 16780224 blocks (8.0 GB)
 
d407: Submirror of d507
 
    State: Okay