Verify Disk Drive Status
4005697 Rev B
51
Verify Disk Drive Status
Follow these instructions to determine whether one or more metadevices have failed
on the system.
1 If necessary, open an xterm window on the DNCS.
2 Type the following command and press Enter.
on the system.
1 If necessary, open an xterm window on the DNCS.
2 Type the following command and press Enter.
metastat
Result: Lengthy output, similar to the following, appears. As you examine the
output, notice devices that have a State of Needs maintenance.
output, notice devices that have a State of Needs maintenance.
d510: Mirror
Submirror 0: d410
State: Okay
Submirror 1: d710
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 50340672 blocks (24 GB)
d410: Submirror of d510
State: Okay
Size: 50340672 blocks (24 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s5 0 No Okay Yes
d710: Submirror of d510
State: Needs maintenance
Invoke: metareplace d510 c1t4d0s5 <new device>
Size: 50340672 blocks (24 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t4d0s5 0 No Maintenance Yes
d507: Mirror
Submirror 0: d407
State: Okay
Submirror 1: d707
State: Needs maintenance
Pass: 1
Read option: roundrobin (default)
Write option: parallel (default)
Size: 16780224 blocks (8.0 GB)
d407: Submirror of d507