Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide
Setting Up a Redundant TED Server
78-4042922-01 Rev B
45
Setting Up a Redundant TED Server
Complete these steps to initialize the PowerKey CAA Keys and the EA Pass Phrase
on the redundant TED 4.0 server.
on the redundant TED 4.0 server.
Before You Begin
Before you begin, you must make sure you meet the following requirements:
The redundant TED server must be another TED 4.0 server.
To ensure the security of your system, a Cisco installer must be present when
you are ready to complete these instructions in this section. Only Cisco installers
know the other portion of the CAA Pass Phrase that is necessary to complete
these instructions.
you are ready to complete these instructions in this section. Only Cisco installers
know the other portion of the CAA Pass Phrase that is necessary to complete
these instructions.
For more information on the pass phrases and on safeguarding your pass
phrases, see Safeguarding Pass Phrases (on page 39).
phrases, see Safeguarding Pass Phrases (on page 39).
Setting Up a Redundant TED 4.0 Server
Complete these steps to provision the redundant TED 4.0 server.
Note: All UNIX commands are case sensitive.
1
Note: All UNIX commands are case sensitive.
1
Power off the primary TED 4.0 server by following these steps:
a Open an xterm window on the DNCS/ISDS.
b Log on to the DNCS/ISDS as root.
c Type ssh -X dncsted and press Enter. A password prompt appears on the
a Open an xterm window on the DNCS/ISDS.
b Log on to the DNCS/ISDS as root.
c Type ssh -X dncsted and press Enter. A password prompt appears on the
screen.
d Type the TED root password and press Enter.
e
e
Type shutdown -g0 -y -i0 and press Enter.
f Wait 60 seconds before proceeding to the next step.
g Press the Power button on the front panel of the TED server to turn the
g Press the Power button on the front panel of the TED server to turn the
power off.
2 Disconnect the RJ-45 cross-over cable from the primary TED Ethernet port.
3 Connect the RJ-45 cross-over cable to the redundant TED Ethernet port.
4 Connect the AC power cords on the back of the redundant TED server to AC
3 Connect the RJ-45 cross-over cable to the redundant TED Ethernet port.
4 Connect the AC power cords on the back of the redundant TED server to AC
power.
5 Power on the redundant TED server.
6 After the TED server boots up, open an xterm window on the DNCS/ISDS.
7 Type ping dncsted and press Enter.
8 Did the message dncsted is alive appear?
6 After the TED server boots up, open an xterm window on the DNCS/ISDS.
7 Type ping dncsted and press Enter.
8 Did the message dncsted is alive appear?
If yes, go to step 9.
If no, contact Cisco Services for assistance.