System Checks 
4031371 Rev E 
57 
 
System Checks 
Network Communications Checks 
camTedChecker 
The camTedChecker is a process that runs on the DNCS/ISDS. By viewing the 
camTedChecker on the DNCS/ISDS Control Panel, you can see the status of the 
communications between the DNCS/ISDS and the TED 3.0 server. 
The camTedChecker process indicates whether or not the TED is running as follows: 
 
Green — the TED is in service and the keys have been initialized 
 
Yellow — the TED software is running, but the keys have not been initialized 
 
Red — the TED software is not running 
 
Verify Communications with the TED Server 
The DNCS/ISDS must be able to communicate with the TED server for the TED 
server to encrypt services in the network. This section provides instructions for 
verifying the communications link between the DNCS/ISDS and the TED server. 
 
Complete these steps to verify that the DNCS/ISDS can communicate with the TED 
server. 
Note: All UNIX commands are case sensitive. 
1  Open an xterm window on the DNCS/ISDS. 
2  Type ping dncsted and then press Enter
3  Did the message dncsted is alive appear? 
 
If yes, you are finished with this procedure. 
 
If no, contact Cisco Services for assistance. 
Network Performance Checks 
After installing or updating the TED 3.0 server, verify that you can receive PPV 
events, IPPV events, make VOD purchases, and receive encrypted channels on a 
local set-top.