Cisco Model D-PCG1000 PowerKEY CAS Gateway Maintenance Manual

Page of 76
 
 
 
Run the Doctor Report 
 
4019476 Rev B 
 
Run the Doctor Report 
Test the Connection to the DNCS (-q Option of the Doctor Report) 
The Doctor Report includes the –q option. Through the –q option, system operators 
can ping the QAM, MQAM, GQAM, and GoQAM modulators and test the remote 
procedure call (RPC) connection between the modulators and the DNCS. 
Furthermore, the –q option generates a report that lists all the modulators, specifies 
whether the modulators are in a quarantined condition, and notes the date and time 
stamp of the quarantine, if applicable. 
 
Running the Doctor Report 
Use the following procedure to run the Doctor Report on the DNCS. 
1  If necessary, open an xterm window on the DNCS. 
2  Type cd  /dvs/dncs/Utilities/doctor and press Enter. The 
/dvs/dncs/Utilities/doctor directory becomes the working directory. 
3  Type doctor and then press Enter. The system generates a list of parameters that 
you can use to run the Doctor Report. 
Note:  Each parameter causes the Doctor Report to generate output with specific 
configuration information.