Chapter 1    Initial Installation of RNCS Software 
 
 
 
78-4021167-01 Rev D 
24  Type shownetwork and press Enter. The system displays the configuration 
settings you just established. 
25  Review the settings you established in steps 9 through 24 and choose one of the 
following options: 
 
If the settings are correct, go to step 26. 
 
If a setting is incorrect, re-run the appropriate command and then go to step 
26. 
26  Type console  -f and press Enter. A message appears that instructs you how to 
return to the ALOM port, if needed. 
27  Press Enter again. 
Results: 
 
Control transfers to the console of the RNCS server (rather than the ALOM 
port). 
 
The ok prompt appears. 
28  Go to 
Choices Regarding Installation (on page 8). 
 
Configuring the ILOM Port of the Sun Netra T5220 Server 
1  Type #. and then press Enter. One of the following results occurs: 
 
The Login prompt appears. 
 
The -> prompt appears. 
2  Did the Login prompt appear after you completed step 1? 
 
If yes, go to step 3. 
 
If no (the -> prompt appeared), go to step 4. 
3  From the login prompt on the terminal, log on using root as the username and 
changeme as the password. 
4  If you want to change the ILOM root password, type set  /SP/users/root 
password and then press Enter
Note:  Enter and re-enter the new password when prompted. 
5  Complete the following steps to configure the serial management port of the 
server. 
a  To disable DHCP for the port, type  
set  /SP/network pendingipdiscovery=static and then press Enter
b  To set the IP address of the port, type 
set  /SP/network pendingipaddress=<xxx.xxx.xxx> and then press Enter
Note:  Replace <xxx.xxx.xxx> with the IP address for the serial management 
port. 
c  To set the Default Gateway for the port, type 
set  /SP/network pendingipgateway=<xxx.xxx.xxx> and then press Enter
Note:  Replace <xxx.xxx.xxx> with the IP address for the Default Gateway.