5 Follow these instructions to confirm that the system correctly mounted the DVD.
a Wait about a minute after having inserted the RNCS installation DVD; then
type df -n and press Enter. A list of mounted file systems appears.
Note: The presence of /cdrom in the output confirms that the system
correctly mounted the DVD
b Did the system correctly mount the DVD?
–
If yes, go to step 6.
–
If no, continue with steps c) and d); then, repeat step a).
c Type /etc/init.d/volmgt stop and then press Enter.
d Type /etc/init.d/volmgt start and then press Enter.
d Type /etc/init.d/volmgt start and then press Enter.
6 As root user in an xterm window on the ISDS, type
siteCmd [hostname] ps -ef | grep dvs and then press Enter.
Example: siteCmd lionn2 ps -ef | grep dvs
Example: siteCmd lionn2 ps -ef | grep dvs
7 Does the output from step 6 reveal that lionn processes are running?
If yes, go to step 8.
If no, troubleshoot the issue to the best of your abilities.
Note: Call Cisco Services if you need assistance.
Note: Call Cisco Services if you need assistance.
8 Type metastat | more and then press Enter. The system displays the status of all
of the metadevices on the RNCS.
Note: Press the Spacebar, if necessary, to page through all of the output.
Note: Press the Spacebar, if necessary, to page through all of the output.
9 Are the following two conditions true?
— The designation Okay appears in the State column next to each metadevice.
— No Hot Spare indicates In Use.
— No Hot Spare indicates In Use.
If yes (to both conditions), go to step 10.
If no (to either or both conditions), call Cisco Services for help in resolving
the issue.
10 Type metastat –c and press Enter. The system displays a list of metadevices on
the system.