Cisco Headend System Release 2.7 Installation Guide
Upgrade the RNCS Software
4012763 Rev B
31
3 Type y and then press Enter.
Results:
A confirmation message appears that instructs the user on how to return to
the ALOM port.
Control of the V240 is returned to the console, rather than the ALOM port.
4 On the DNCS, open another xterm window.
5 From this xterm window, telnet into the Sun Fire V240 server.
5 From this xterm window, telnet into the Sun Fire V240 server.
Example: telnet lionn1 or telnet <IP address of Sun Fire V240 server>.
6 Log on to the Sun Fire V240 server as root user.
7 In the event that there is an existing CD or DVD in the drive of the server, type
7 In the event that there is an existing CD or DVD in the drive of the server, type
eject cdrom and then press Enter.
8 Ask the on-site technician at the RNCS server to insert the DVD, labeled
similarly to RNCS Install DVD, into the DVD drive of the RNCS server.
9 Follow these instructions to stop and restart the vold process, which manages the
auto-mount functions for the CDROM drive.
a Type /etc/init.d/volmgt stop and then press Enter.
b Type /etc/init.d/volmgt start and then press Enter.
a Type /etc/init.d/volmgt stop and then press Enter.
b Type /etc/init.d/volmgt start and then press Enter.
10 From an xterm window on the DNCS, type siteCmd <hostname> "ps -ef |
grep dvs" and then press Enter.
Example: siteCmd lionn1 "ps -ef | grep dvs"
Example: siteCmd lionn1 "ps -ef | grep dvs"
11 Does the output from step 10 reveal that lionn processes are running?
If yes, go to step 12.
If no, troubleshoot the issue to the best of your abilities.
Note: Call Cisco Services if you need assistance.
Note: Call Cisco Services if you need assistance.
12 Type metastat and then press Enter to verify that all metadevices have a state of
ok.
Note: If any device displays a needs maintenance message, correct the issue
Note: If any device displays a needs maintenance message, correct the issue
before proceeding. Contact Cisco Services if you need assistance.
13 Type cd /cdrom/cdrom0/s0/sai/scripts and then press Enter. The
/cdrom/cdrom0/s0/sai/scripts directory becomes the working directory.
14 Type ./V240_detach_mirrors and then press Enter. A confirmation message
appears.
15 Type y and then press Enter.
16 Type metastat and then press Enter to verify that the d7xx mirrors are no longer
16 Type metastat and then press Enter to verify that the d7xx mirrors are no longer
shown.
Note: Contact Cisco Services if the d7xx mirrors are still displayed.
Note: Contact Cisco Services if the d7xx mirrors are still displayed.
17 Type ./LU_V240 and then press Enter. A confirmation message appears.