Cisco Headend System Release 2.7 User Guide

Page of 117
5-6 
Examine the Database for Expiring EMMs With the emm_check Utility 
749640 Rev C 
Analyze the Output of the emm_check Utility,
 Continued 
Database Check 2 — secure_micro Rows 
The second database check verifies that each secure micro serial number entry in the 
secure_micro table has a corresponding entry in the hct_profile table. The system 
then uses the deleteDhct utility to delete any entries in the secure_micro table that do 
not have a corresponding entry in the hct_profile table. 
Three scenarios are possible as a result of running the second database check: 
• 
When the system finds that each secure micro serial number entry in the 
secure_micro table has a corresponding entry in the hct_profile table, it displays 
the following message: 
Checking for secure_micro rows with SMSN not in hct_profile. 
There are 0 secure_micro MACs with sm_serial_num not in hct_profile … 
• 
When the system finds secure micro serial number entries in the secure_micro 
table without corresponding entries in the hct_profile table, and is able to use the 
deleteDhct utility to delete the secure micro serial number entries, it displays a 
message similar to the following: 
Checking for secure_micro rows with SMSN not in hct_profile. 
There are 2 secure_micro MACs with sm_serial_num not in hct_profile. 
  Deleting: MAC=00:02:DE:E5:E7:E6,  OOS , SN=SABCGWFJT, SMSN=00:02:DE:F0:2F:97 
                    MAC=00:02:DE:E5:E7:E6 ........ Mismatched   SMSN=00:02:DE:DA:FD:93 
  Deleting: MAC=00:02:DE:7C:C4:22,  OOS , SN=SABBTWPRB, SMSN=00:01:A6:78:58:F6 
                    MAC=00:02:DE:7C:C4:22 ........ Mismatched   SMSN=00:02:DE:97:B9:87
 
2 secure_micros with SMSN not in hct_profile were DELETED! 
Note:  
The “2 secure_micro rows” referenced in this example are for illustration 
purposes, only. 
• 
When the system finds secure micro serial number entries in the secure_micro 
table without corresponding entries in the hct_profile table, and is unable to use the 
deleteDhct utility to delete the secure micro serial number entries, it displays a 
message similar to the following: 
Checking for secure_micro rows with SMSN not in hct_profile. 
There are 2 secure_micro MACs with sm_serial_num not in hct_profile. 
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  
A serious EMM ‘timeout’ condition is beginning to develop! 
Automatic repair can not occur because the deleteDhct 
utility can not be found. Please install this utility and 
then re-run these tests. Call Cisco Services for help, if needed. 
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
Due to earlier errors, the third test is likely not valid. 
Therefore, this script is terminating. 
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
Please rerun the script again in 24 hours to check that 
the third test runs cleanly. 
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 