Cisco Headend System Release 2.7 User Guide
5-6
Examine the Database for Expiring EMMs With the emm_check Utility
749640 Rev C
Analyze the Output of the emm_check Utility,
Continued
Database Check 2 — secure_micro Rows
The second database check verifies that each secure micro serial number entry in the
secure_micro table has a corresponding entry in the hct_profile table. The system
then uses the deleteDhct utility to delete any entries in the secure_micro table that do
not have a corresponding entry in the hct_profile table.
Three scenarios are possible as a result of running the second database check:
•
Three scenarios are possible as a result of running the second database check:
•
When the system finds that each secure micro serial number entry in the
secure_micro table has a corresponding entry in the hct_profile table, it displays
the following message:
Checking for secure_micro rows with SMSN not in hct_profile.
Checking for secure_micro rows with SMSN not in hct_profile.
There are 0 secure_micro MACs with sm_serial_num not in hct_profile …
•
When the system finds secure micro serial number entries in the secure_micro
table without corresponding entries in the hct_profile table, and is able to use the
deleteDhct utility to delete the secure micro serial number entries, it displays a
message similar to the following:
Checking for secure_micro rows with SMSN not in hct_profile.
Checking for secure_micro rows with SMSN not in hct_profile.
There are 2 secure_micro MACs with sm_serial_num not in hct_profile.
Deleting: MAC=00:02:DE:E5:E7:E6, OOS , SN=SABCGWFJT, SMSN=00:02:DE:F0:2F:97
MAC=00:02:DE:E5:E7:E6 ........ Mismatched SMSN=00:02:DE:DA:FD:93
Deleting: MAC=00:02:DE:7C:C4:22, OOS , SN=SABBTWPRB, SMSN=00:01:A6:78:58:F6
MAC=00:02:DE:7C:C4:22 ........ Mismatched SMSN=00:02:DE:97:B9:87
2 secure_micros with SMSN not in hct_profile were DELETED!
Note: The “2 secure_micro rows” referenced in this example are for illustration
Note: The “2 secure_micro rows” referenced in this example are for illustration
purposes, only.
•
When the system finds secure micro serial number entries in the secure_micro
table without corresponding entries in the hct_profile table, and is unable to use the
deleteDhct utility to delete the secure micro serial number entries, it displays a
message similar to the following:
Checking for secure_micro rows with SMSN not in hct_profile.
Checking for secure_micro rows with SMSN not in hct_profile.
There are 2 secure_micro MACs with sm_serial_num not in hct_profile.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
A serious EMM ‘timeout’ condition is beginning to develop!
Automatic repair can not occur because the deleteDhct
utility can not be found. Please install this utility and
then re-run these tests. Call Cisco Services for help, if needed.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Due to earlier errors, the third test is likely not valid.
Therefore, this script is terminating.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Please rerun the script again in 24 hours to check that
the third test runs cleanly.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Continued on next page