Cisco Headend System Release 2.7 Maintenance Manual

Page of 202
 
Chapter 2    Optimize Your System Performance for Downloads and Staging 
 
 
 
46 
4024836 Rev D 
Turn Off Inband SI 
System information (SI) is tuning data sent to CableCARD modules. The default 
configuration in the DNCS is to send SI as both inband and out-of-band data. This 
configuration is due to the way in which previous versions of DHCT software 
operated, and it has not been a requirement in recent years. At this time, we 
recommend that sites only send SI out-of-band. This helps stabilize the CableCARD 
download environment. 
Note: Refer to Recommendation for Setting System Information to Out-of-Band (part 
number 738143) for procedures to turn off inband SI. 
 
Configuring a Default Download Image 
We recommend having the same image on all of your deployed CableCARD 
modules and downloading that same image onto both new and factory repaired 
CableCARD modules. This recommendation creates a consistent environment for all 
cards in your system. 
Using group-based downloads will limit which cards use a particular version of 
code. For this reason, if you choose to implement group-based downloads, we 
recommend configuring a download that sends the most current CableCARD 
software (for example, CableCARD software release 1.1.x) to the default CableCARD 
group. 
Important: If you are running CableCARD software that precedes software release 
1.1 and you are using an OSM download method, do not send any download-related 
UN-Config messages to the CableCARD hardware type list. For details, see Avoid 
Sending Download-related UN-Config Messages. 
Sending the most current CableCARD software to the default group achieves the 
following results: 
 
Eliminates the need to use CVT groups for CableCARD downloads 
 
Provides a standard release with the most recent version of code on all 
CableCARD modules