Cisco Headend System Release 2.7 Installation Guide

Page of 138
 
Chapter 3    SR 2.8.2/3.8.2/4.3.2 Post-Upgrade Procedures 
 
 
 
78 
4038415 Rev A 
Verify SAM Timers 
After you upgrade your system to SR 2.8.2/3.8.2/4.3.2, the Update Timer and 
Schedule Timer fields on the SAM Configuration window should be set to the 
values they held prior to the upgrade. These values ensure that channel maps and 
the database have sufficient time to update. You recorded these values in Check 
SAM Timers
 (on page 20). Follow the instructions in this section to set the Update 
Timer
 and Schedule Timer fields to their appropriate values. 
Note:  This procedure pertains only to sites that support SARA. Skip this procedure 
if the site you have upgraded does not support SARA. 
 
Verifying the SAM Timers 
Follow these instructions to set the Update Timer and Schedule Timer fields on the 
SAM Configuration window, if required. 
Note:  These examples show values of 600 and 1200 for the Update Timer and 
Schedule Timer fields, respectively, which are the Cisco-recommended values. You 
should actually set these fields to the values required by your system. 
1  From the DNCS Administrative Console, select the Application Interface 
Modules tab and then click SAM Config. The SAM Configuration window 
opens. 
2  Follow these instructions to configure the SAM Configuration window. 
a  In the Update Timer field, type 600 or the value required by your system. 
b  In the Schedule Timer field, type 1200 or the value required by your system. 
 
3  Click Save