Cisco Prisma II bdr Dig Rev 2 1 Dual Mux Sys for High Density Installations Data Sheet

Page of 8
Prisma II bdr Digital Reverse 2:1 Dual Multiplexing System 
for High Density Installations 
 
4
 
 
Module Specifications 
 
2:1D Transmit Processor 
Units 
 
Notes 
RF Input Level Requirements 
dBmV/Hz 
See Link Performance Section 
 
RF Input Return Loss 
dB 
16 
 
Input RF Variable Attenuation Range 
dB 
0 to 10 
 
Power Consumption (maximum) 
11 
 
Data Output to Laser Module 
Gbps 
2.5 
 
A/D Input Test Point 
dB 
-20 
± 0.5 
 
Laser Module 
Units 
 
Notes 
Data Input from 2:1 Transmit Processor 
Gbps 
2.5  
 
Optical Wavelength 
nm 
1550 ITU grid 200 GHz spacing 
1550 non-ITU 
1310 nm 
 
Power Consumption (maximum) 
W
 
8 (1550 nm ITU) 
6.5 (1550 non-ITU) & (1310 nm) 
 
Optical Output Power (modulated) 
dBm 
0 or 7 
 
Optical Interface 
 
SC/APC Connector 
 
 
2:1D Receive Processor 
Units 
 
Notes 
Data Input from Receiver Module 
Gbps 
2.5 
 
RF Output Level 
dBmV/Hz 
See Link Performance Section 
 
RF Output Return Loss 
dB 
16 
 
Output RF Variable Gain Control Range 
dB 
0 to -10 
 
Power Consumption (maximum) 
15 
 
RF Output Test Point  
dB 
-20 (
± 0.5 dB) 
 
Receiver Module 
Units 
 
Notes 
Optical Input Power Range: SR module 
dBm 
-5 to –22 
Optical Input Power Range: ER module 
dBm 
-10 to -29 
Data Output to Laser Module 
Gbps 
2.5 
 
Power Consumption (maximum) 
 
Optical Interface 
 
SC/APC connector 
 
 
Mechanical 
Units 
 
Notes 
Operating Temperature Range (ambient) 
°C 
°F 
-40 to +65 
-40 to +149 
3,4 
Physical Dimensions  (any Processor with 
2 Receiver or 2 Laser Modules) 
    Depth 
 
 
in. 
cm 
 
 
9.8 
24.9 
 
    Width 
in. 
cm 
2.1 
5.3 
 
    Height 
in. 
cm 
7.6 
19.3 
 
    Weight 
lb 
kg 
5.0 
2.3 
 
 
 
Notes:  
1.  Test point level is –20 dB referenced to the RF input with attenuator set at 0 dB. 
2.  System designs should consider the effects of wavelength dispersion in long fiber lengths.  This can result in up to 2 
dB loss of Rx sensitivity over a 100 km distance. 
3.  Recommended for use only in non-condensing environments. 
4.  Receive Processor operating temperature range is –10 to +65°C.