Bootloader Error Codes 
4025012 Rev B 
39 
 
Example: The Tuning Adapter displays the following code: 
4 blinks, [2 dim, 2 bright, 4 dim], 4 blinks, [2 dim, 2 bright, 4 dim], 4 blinks, etc. 
This blinking pattern (between the brackets [ ] in the example above) represents a 
binary code of 0011 0000 (hex 0x60). You refer to the error codes in this document 
and see that this error indicates that the image length is incorrect. 
 
BootLo Error Codes 
The following table contains the bootLo error codes that might display on the 
Tuning Adapter. 
Important: The bootLo error codes are 2-byte codes. 
Illuminations  Codes  Binary  Hex  Error Indication 
dim, dim 
00 
00 
0x00  One of the clock initializations failed. 
dim, bright 
01 
01 
0x01  Loading bootHi failure. 
bright, dim 
10 
10 
0x10  bootHi load memory failure. 
bright, bright  11 
11 
0x11  bootHi security check failure. 
 
 
BootHi Error Codes 
The following table contains the bootHi error codes that might display on the 
Tuning Adapter. 
Illuminations  
Binary 
Hex 
Error Indication 
2 dim, 1 bright, 5 dim 
0010 0000  0x20 
Failed reception after the 
maximum retries. 
2 dim, 1 bright, 4 dim, 1 bright 
0010 0001  0x21 
Transfer parameters are 
incorrect. 
2 dim, 1 bright, 3 dim, 1 bright, 1 
dim 
0010 0010  0x22 
CRC on the received image 
is incorrect. 
2 dim, 1 bright, 3 dim,  2 bright 
0010 0011  0x23 
Wrong address 
(overflow/underflow). 
2 dim, 1 bright, 2 dim, 1 bright, 2 
dim 
0010 0100  0x24 
Start offset error. 
2 dim, 1 bright, 2 dim, 3 bright 
0010 0111  0x27 
Overflow - Image is too 
long. 
2 dim, 2 bright, 4 dim 
0011 0000  0x30 
Image length wrong. 
2 dim, 2 bright, 3 dim, 1 bright 
0011 0001  0x31 
CRC in signature failed. 
2 dim, 2 bright, 2 dim, 1 bright, 1 
dim 
0011 0010  0x32 
Signature values wrong.