Cisco Model D-PCG1000 PowerKEY CAS Gateway Release Notes

Page of 46
 
Chapter 2    Upgrading the Software 
 
 
 
24 
4021639 Rev B 
Resetting More Than One GoQAM 
When performing an upgrade, you may not want to manually reset hundreds of 
modulators from the DNCS GUI. To save time, you can create a script that resets the 
modulators. Refer to the following example for a sample script. 
Important: Resetting the modulator interrupts all active sessions on the modulator 
for up to 10 minutes. Complete this task during a maintenance window whenever 
possible. 
This sample script will execute the following functions: 
 
Reset four modulators. 
 
After 5 minutes (300 seconds), reset another set of four modulators. 
Important: Use the procedure for Preparing to Monitor Remote GoQAM Resets (on 
page 20) when using an auditQam script to reset multiple modulators. 
Note: You can save and re-use this script each time you need to reboot your 
modulators. 
auditQam  -reset  123.123.123.123 
sleep 1 
auditQam  -reset  123.123.123.124 
sleep 1 
auditQam  -reset  123.123.123.125 
sleep 1 
auditQam  -reset  123.123.123.126 
sleep 300 
# end of first set 
auditQam  -reset  123.123.123.127 
sleep 1 
auditQam  -reset  123.123.123.128 
sleep 1 
auditQam  -reset  123.123.123.129 
sleep 1 
auditQam  -reset  123.123.123.130 
sleep 300 
# end of second set 
After resetting the modulators, select one of the following options: 
 
For modulators that carry broadcast sessions, go to Verifying the Functionality 
of GoQAM Modulators That Carry Broadcast Sessions
 (on page 26). 
 
For modulators that carry xOD or VOD sessions, go to Verifying the 
Functionality of GoQAM Modulators That Carry xOD or VOD Sessions
  
(on page 27).