Cisco Model D-PCG1000 PowerKEY CAS Gateway Release Notes

Page of 40
 
 
Download Software to the Netcrypt Bulk Encryptors 
4009746 Rev B 
21 
 
Verifying the Functionality of Modulators That Carry Netcrypt-Encrypted 
Broadcast Sessions 
1  Access a DHCT that is connected downstream to one Netcrypt Bulk Encryptor. 
2  Tune the DHCT to each channel that uses a source from a Netcrypt Bulk 
Encryptor that you reset and upgraded. 
3  Are all channels for the Netcrypt Bulk Encryptors that you reset accessible from 
the DHCT? 
 
If yes, go to step 5. 
 
If no, do not attempt to upgrade the software for any additional Netcrypt 
Bulk Encryptors. Call Cisco Services. 
4  For those Netcrypt Bulk Encryptors that carry content inappropriate for children, 
Cisco recommends that you verify encryption using one of the following 
methods: 
 
Using a set-top that is authorized for all services, tune one-by-one to each 
service and check the PowerKEY Information diagnostic screen (page 6). If 
the Prog Stat and Prog Entitle fields are zero (0x00), then the program is in 
the clear. If these fields are non-zero, then the program is encrypted. 
 
Using a QAM tuner television, tune to the respective channels and verify that 
inappropriate content is not viewable. 
 
5  Have you completed resetting your Netcrypt Bulk Encryptors? 
 
If yes, go to step 6. 
 
If no, return to the procedure you are using to reset your Netcrypt Bulk 
Encryptors. 
6  Generate a Doctor Report using the –av option to verify system stability and 
functionality. 
Note: For further instructions on running the Doctor Report, refer to  
the chapter titled Analyze System Configuration With the Doctor Report in the 
DBDS Utilities Version 6.1 Installation Instructions and DNCS Utilities User’s Guide
7  Do new or unexpected errors appear in the Doctor Report? 
 
If yes, contact Cisco Services. 
 
If no, go to step 8. 
8  Perform the System Validation Tests found in the installation and upgrade 
documentation for your system release version to verify the functionality and 
performance of the set-tops in your system. 
9  Over the next few days, check the individual modulators that receive Netcrypt-
encrypted sessions to verify that they are functioning as expected.