Cisco Headend System Release 2.7 Release Notes

Page of 70
 
 
Stop System Components 
4019303 Rev C 
29 
 
Stopping the RNCS Processes on the DNCS 
If the RNCS licensed feature is enabled on your DNCS, then refer to the RNCS 
Installation and Upgrade Instructions
 (part number 4003191) to stop the RNCS 
processes. 
 
Stopping the Application Server 
This section provides procedures for stopping either a SARA Server or an Aptiv 
Application Server. Choose the procedure that pertains to your system. 
 
Stopping the Application Server at SARA Sites 
1  
Press the middle mouse button on the Application Server and select App Serv 
Stop
2  From an xterm window on the Application Server, type appControl and then 
press Enter. The Applications Control window appears. 
3  Type (for Startup/Shutdown Single Element Group), and then press Enter. The 
system displays all Application Server processes. 
Note: The system updates the display periodically, or you can press Enter to 
force an update. 
4  When the Curr Stt (Current State) field of the Applications Control window 
indicates that all of the Application Server processes have stopped, follow the 
on-screen instructions to close the Applications Control window. 
5  Type appKill and then press Enter. The appInitd process stops. 
 
Stopping the Time Warner Mystro Application Server 
If the site you are upgrading uses the Time Warner Mystro Application Server 
(MDN), refer to the documents provided by Mystro to shut down the Mystro 
Application Server. 
 
Preparing the Aptiv Application Server for the Service Pack 
Refer to Aptiv Technical Note Number 41. Complete steps 1 through 3 to prepare 
the Aptiv Application Server for the service pack upgrade. 