Cisco Headend Digital Broadband Delivery System Technical References

Page of 5
 
4017871 Rev G 
 
Customer-Impacting Issues 
 
DST Date is Missing From Timer Option Menu 
Subscribers who attempt to set any system timers after 11:00 p.m. on the day prior to 
DST will find that the system omits the DST date. Subscribers cannot select the DST 
date from any of the system timers. 
Workaround:  There is no workaround for this issue. 
Affected Code:  All DVR and non-DVR releases 
 
DST Date Missing From Guide When Using DAY Option on Remote 
Control 
When subscribers use the DAY option on the remote control after 11:00 p.m. on the 
day prior to DST, the system skips entirely the DST date, and advances instead to the 
day following DST. 
Workaround:  There is no workaround for this issue. 
Affected Code:  All DVR and non-DVR releases 
 
effective_year Field Missing from dst_rules Table 
In a DNCS upgrade script (bldDncsDb), a field name in the dst_rules table was 
changed from "effective_year" to "efective_year". The system interpreted this as a 
new field and assigned it a default value of -1, which may result in an inaccurate 
value in the Effective Year field in the DST GUI. 
Workaround:  Follow these steps to address the issue: 
1  Access the DST GUI on the DNCS. 
2  Select 2011 from the Effective Year drop-down menu. 
Click Save.  
 
Affected Releases: SR 4.4 and later 
CDETS Number:  CSCzk37807