Cisco Model D-PCG1000 PowerKEY CAS Gateway Technical References
January 2004
Operations Alert Bulletin
Ensuring Installation of the TED FX Rev D
Software During an Upgrade
Software During an Upgrade
Purpose
This operations alert bulletin is to notify Cisco® Services field service engineers and
system engineers at customer sites using the Rev D Transaction Encryption Device
(TED) FX, that they must reinstall the TED FX software after a system upgrade.
Upgrade personnel should follow the recommendations in this alert bulletin when
upgrading the Digital Network Control System (DNCS) software.
Sites Affected
This alert bulletin applies to sites using the Rev D TED FX that are upgrading their
DNCS to SR 1.5, SR 2.1, SR 2.1.x, SR 3.0.x, SR 2.2, or SR 3.2.
Important: This operations alert bulletin does not apply to sites upgrading to
Important: This operations alert bulletin does not apply to sites upgrading to
SR 3.3 or later because SR 3.3 already contains the new TED FX software.
Audience
This alert bulletin is written for Cisco Services field service engineers and system
engineers responsible for upgrading systems at customer sites.
Background
The TED FX (part number 733153) Rev D server requires TED FX software
v. 3.2.0.0 to be loaded onto the DNCS in order to function properly. This new TED
FX software ships on a CD with the Rev D TED FX. When sites upgrade their DNCS,
the upgrade procedure overwrites the TED FX software that is currently installed on
the DNCS. Sites using the TED FX (part number 733153) Rev D server must reinstall
the TED FX v. 3.2.0.0 software onto the DNCS after the upgrade to ensure that the
correct software version is on the system.