Cisco Model D-PCG1000 PowerKEY CAS Gateway Technical References

Page of 6
 
Provisioning the Gigabit Ethernet Port on the Gigabit QAM Modulator  
4002333 Rev B 
Verify the GbE IP Address 
Introduction 
After you provision the GbE IP address and reset the GQAM, you must verify that 
you correctly provisioned the GbE IP address. This section provides a procedure for 
verifying the GbE IP address. 
Verifying the GbE IP Address 
Complete these steps to verify the GbE IP address. 
Important:  If you came here directly from the previous procedure, Provisioning the 
GbE IP Address, skip steps 1 and 2, and go directly to step 3 of this procedure. 
Otherwise, begin with step 1. 
1. 
Connect a diagnostic PC to the CRAFT PORT on the back panel of the 
GQAM using a straight cable with a male DB-9 connector. 
Note:  A diagnostic PC is a laptop or desktop PC that contains Procomm or 
any other compatible terminal program and a DB-9 port. 
2. 
Power on the diagnostic PC and activate a Procomm or Hyperterminal 
window using the following modem connection settings: 
• 
9600 baud 
• 
1 stop bit 
• 
No parity 
• 
8 data bits 
• 
No flow control 
3. 
At the > prompt, type gigaipaddr and press Enter
Result:  The GbE IP address displays on the screen. 
4. 
Is the GbE IP address correct? 
• 
If yes, go to step 5. 
• 
If no, repeat steps 3 and 4 of Provisioning the GbE IP Address, earlier in 
this technical bulletin, and then repeat step 3 of this procedure. If the GbE 
IP address is still incorrect, contact Cisco Services for further assistance. 
5. 
Power off and then disconnect the diagnostic PC from the CRAFT PORT