Cisco GainMaker High Gain Dual System Amplifier 1 GHz with 55 70 MHz Split Data Sheet

Page of 5
GainMaker
®
 - Line Extender - 5-55/70-1002 MHz 
 
3
 
Specifications 
 
General Station Performance 
Units 
Forward 
Reverse 
Notes 
Pass Band 
MHz 
70-1002 
5-55 
 
Amplifier Type 
--- 
GaAs FET 
PP 
 
Frequency Response 
dB 
± 0.5  
± 0.5 
 
Auto Slope and Gain Range 
dB 
± 5 
N/A  
Return Loss 
dB 
16 
16 
Max AC Through Current (continuous) 
Amps 
15 
--- 
 
Max AC Through Current (surge) 
Amps 
25 
--- 
 
Hum Modulation @ 12 A 
(over specified frequency range) 
dB 
70 (70-870 MHz) 
60 (870-1002 MHz) 
60 (5-10 MHz) 
70 (11-55 MHz) 
 
Hum Modulation @ 15 A 
(over specified frequency range) 
dB 
65 (70-870 MHz) 
60 (870-1002 MHz) 
60 (5-10 MHz) 
65 (11-55 MHz) 
 
Test Points (
± 0.5 dB) 
dB -20 
-20   
35  (@ 55 MHz) 
 
 
 
 
 
 
 
Reference Output Level @…          1002 MHz 
870 MHz 
750 MHz 
650 MHz 
550 MHz 
70 MHz 
dBmV 49.5 
47.5 
45.7 
44.0 
42.5  
35.3 
35  (@ 5 MHz) 
 
Reference Output Tilt  (70-1002 MHz) 
dB 
14.2  
 
Forward Station Performance 
Units 
Manual 
Thermal 
AGC 
Notes 
Operational Gain 
dB 
37 
32 
31 
Internal Tilt (
± 0.5 dB) 
dB +9.1  +9.1  +9.1 3 
Noise Figure @ 70 MHz 
dB 
6.0 
7.5 
7.5 
Noise Figure @ 1002 MHz 
dB 
7.0 
7.0 
7.0 
64 PAL B/G Channels (CW) with digital 
 
 
 
 
Composite Triple Beat 
dB 
82 
80 
80 
 
Cross Modulation 
dB 
74 
74 
73 
Composite Second Order (high side) 
dB 
75 
75 
75 
 
64 PAL I Channels (CW) with digital 
 
 
 
 
10 
Composite Beat 
dB 
75 
73 
73 
Cross Modulation 
dB 
76 
73 
72 
42 CENELEC Channels (CW) 
 
 
 
 
Composite Triple Beat 
dBuV 
114 
113 
113.5 
 
Cross Modulation 
dBuV 
112 
110.5 
111.5 
Composite Second Order  
dBuV 
115 
115 
116 
 
78 NTSC Channels (CW) with digital 
 
 
 
 
11 
Composite Triple Beat 
dB 
81 
79 
79 
 
Cross Modulation 
dB 
76 
73 
72 
Composite Second Order (high side) 
dB 
76 
75 
75 
 
 
Reverse Station Performance 
Units 
 
Notes 
Operational Gain (minimum) 
dB 
19.5 
6,7 
Internal Tilt (
± 0.5 dB) 
dB 0 
Noise Figure 
dB 
6,7 
CENELEC Distortions 
 
 
Discrete Third Order 
dBuV 
114 
 
Discrete Second Order 
dBuV 
120 
 
6 NTSC Channels (CW) 
 
 
 
Composite Triple Beat 
dB 
92 
 
Cross Modulation 
dB 
80 
Composite Second Order (high side) 
dB 
82 
 
 
 
 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C).  Specifications are based 
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.