Cisco Cisco TNCS Element Management System Data Sheet

Page of 5
 
 
 
 
Description 
This full frequency agile transponder is designed to interface 
with Scientific-Atlanta’s GainMaker
 Nodes.  It is controlled by 
Scientific-Atlanta’s ROSA
 Element Manager (EM) and 
Transmission Network Control System (TNCS) element 
management systems. 
 
The transponder monitors the operational parameters of the 
amplifier station and allows remote control of certain amplifier 
functions.  Communications to and from the transponder are 
accomplished via the built in forward RF data carrier receiver 
and reverse RF data carrier transmitter. 
 
The transponder communicates with the ROSA EM and TNCS element management systems via the Phoenix
 
RF Modem.  The cutting-edge RF technology used in the Phoenix modem allows operation in networks that suffer 
from a high level of ingress noise in the return path. 
 
The transponder monitors a wide range of operational parameters, including: 
  Optical receive power for the primary and secondary receivers 
  Optical transmit power of the transmitter 
  RF level of the forward status monitor data carrier 
  AC and DC power supply voltages 
 Transponder 
temperature 
  Open/closed housing status 
 
If the status of any monitored parameter is outside of established thresholds, the centrally located element 
management console can activate an alarm.  All alarm thresholds are remotely adjustable from the console.  The 
transponder also enables remote control of the reverse “On/-6 dB/Off” RF switches (for remote isolation of 
ingress) and of the power supply. 
 
The transponder is packaged in an aluminum housing that mounts directly in the lid of the GainMaker Optical 
Node.  The only tool required to mount the transponder is a flat-blade screwdriver.  There are no cables required 
to connect the transponder.  Once installed, LEDs on the transponder indicate; “Power On”, “Receiving Data”, and 
/ or “Error” condition. 
 
This transponder is easily configured for operation with the use of a Handheld Programming Terminal.  
Configuration can be performed either on the bench or in the field, prior to installation. 
 
Features 
  Plug-in compatibility with the GainMaker Optical Node 
  Frequency agile 5 to 65 MHz for reverse path 
  Frequency agile 45 to 174 MHz for forward path 
  Monitors all critical internal station parameters 
  Controls all switches within the node  
  Simple and efficient installation 
  Wide operating temperature range 
 
 
Element Management 
Transponder for  
GainMaker
 Optoelectronic Node