Cisco Cisco Workload Automation 6.3 User Guide
234
Events
Event Types
System Events Dialog
The
System Events
dialog displays when you add or edit a system event.
Common to All Tabs
Event Name
– The name of the system event (up to 30 characters).
Event Trigger
– The condition that causes CWA to trigger the assigned (associated) action(s).
Owner
– The owner of the system event. By default, the creator is the owner.
Public
– Makes this event available to all users of CWA as allowed by their security policy. You can create a default
for this option on the
Defaults
tab in the
System Configuration
dialog.
Enabled flag
– Makes the system event available for use. When this option is cleared, the event cannot be triggered
by the master. If the system event is inactive, the system event cannot be monitored by the master. Note that there
are some major events that are always reported, with or without specifically defined system events.
are some major events that are always reported, with or without specifically defined system events.
Associated Action(s) Tab
This tab associates action(s) with the system event. An event must have an associated action before it can be enabled.
For information about the fields on this tab, refer to
For information about the fields on this tab, refer to
Description Tab
This is a free text field where you can provide a description and notes about the system event (up to 255 characters).
Trigger History Tab
The
Trigger History
tab lists all of the instances when the event was triggered during the trigger history retention
period. This retention period is configured on the
Default
tab of the
System Configuration
dialog. For information
about the fields and options on this tab, refer to the
.
Variable Events
About Variable Events
An event monitor can be defined to watch a designated variable on a master. Whenever the variable matches a specified
value it becomes an event that triggers an assigned action.
value it becomes an event that triggers an assigned action.
Variable Event Definition Dialog
A variable monitor is defined from the
Variable Event Definition
dialog. The
Variable Event Definition
dialog
displays whenever you add or edit a variable event.
In the
Navigator
pane, select
Definitions>Events>Variable Events
to display the
Variable Events
pane. To
display the
Variable Event Definition
dialog, either right-click in the pane in the
Variable Events
pane and select
Add Event
from the context menu or click the
Add Event
button.
Common to All Tabs
Event Name
– The name of the system event (up to 30 characters).
Owner
– The owner of the system event. By default, the creator is the owner.
Public
– Makes this event available to all users of CWA as allowed by their security policy. You can create a default
for this option on the
Defaults
tab in the
System Configuration
dialog.