Cisco Continuum DVP eXtra Dense QAM Array (XDQA) for VoD Delivery Data Sheet

Page of 3
Continuum DVP eXtra Dense QAM Array 24 (XDQA24) 
for Video-on-Demand Delivery 
 
2
 
Specifications 
 
GbE Input Interface 
Number of inputs 
1+1 (for redundancy) 
Connector 
Optical/electrical Small Form Factor Pluggable (SFP) 
(2)
 
Interface type 
Gigabit Ethernet according to IEEE 802.3ab (Electrical) 
or IEEE 802.3z (Optical) 
Data rate 
960 Mbps 
Syntax 
VBR and CBR MPEG SPTS and MPTS on UDP (RFC-768) 
RF Outputs 
Number of outputs 
Max. 12 x 1 (each with 2 adjacent QAM channels) 
Connector F-type, 
75 
Ω 
Frequency  
Range 
Step size  
Stability 
Accuracy 
 
Channel edges between 45 and 1000 MHz (tunable) 
25 kHz 
± 3 ppm 
± 3 ppm 
Channel Bandwidth  
6, 7 or 8 MHz depending on QAM transmission standard 
Level  
Range 
Stability 
Accuracy 
 
45 to 55 dBmV RMS per QAM Channel in 0.5 dB steps 
± 1 dB 
± 1 dB  
Active channel Return Loss (typical) 
14 dB (45-750 MHz) 
13 dB (750-870 MHz) 
12 dB (870-1000 MHz) 
Inter-channel carrier suppression 
50 dBc 
Management Interface 
Interface type 
Ethernet 10/100 Base-T 
Connector RJ-45 
Protocols 
HTTP, SNMP, HTML, JAVA, FTP 
Signal Specifications 
Channel encoding  
Scrambling, Reed-Solomon, Trellis and Interleaving 
according to ITU-T Annex A, B or C 
MER (before equalizer) 
≥ 35 dB (at RF) 
MER (after equalizer) 
≥ 43 dB (at RF) 
BER (256 QAM) 
≤ 5.10
-9
 (ITU-A/C pre FEC) 
≤ 1.10
-13
 (ITU-B pre FEC / post trellis) 
QAM constellations 
64 & 256 QAM 
Environmental Specifications 
Operating temperature 
+32°F to +122°F (0° to +50°C) 
Storage temperature 
-40°F to +158°F (-40° to +70°C) 
Altitude 
-200 to +10000 feet AMSL 
Operating humidity 
5% to 95%, non-condensing 
Power supply (nominal) 
100 to 240 V AC or -48 V DC 
Normal service voltage range 
90 to 254 V AC or -38 to -58 V DC 
Power consumption (fully loaded) 
< 230 W 
Chassis Mechanical Specifications 
Height 
1.75 in. / 44.45 mm (1 RU) 
Width 
19 in. / 482.6 mm 
Depth 
21.0 in. / 533.4 mm 
Weight 
16.5 lbs / 7.48 kg 
 
(2) SFP Module not included