Page 16 
vPC role                        : primary 
Number of vPCs configured       : 0 
Peer Gateway                    : Disabled 
Dual-active excluded VLANs      : - 
Graceful Consistency Check      : Enabled 
 
vPC Peer-link status 
--------------------------------------------------------------------- 
id   Port   Status Active vlans 
--   ----   ------ -------------------------------------------------- 
1    Po20   up     1,182 
N5548-Bottom(config-if)# 
 
Now the two switches have been configured to support vPC links to other devices. These connections can be 
used for upstream links to the data center core. These vPC links can be used for connections to hosts in the data 
center, allowing additional bandwidth and redundant links. 
Server Network Teaming 
Server NIC teaming provides an additional layer of redundancy to servers. It makes it possible for multiple links to 
be available, for redundancy. In the blade server environment, server network teaming typically is limited to 
active-standby configurations and cannot provide active-active links, because active-active links require an 
EtherChannel or Link Aggregation Control Protocol (LACP) connection to a single switch. However, because the 
Cisco Nexus B22 for IBM fabric extender is an extension of the parent switch, EtherChannel or LACP connections 
can be created between the blade server and the virtual chassis. Dual Cisco Nexus switches can be used with 
vPC for additional switch redundancy while providing active-active links to servers, thus enabling aggregate 40-
Gbps bandwidth with dual links (Figure 6). 
Figure 6:    Fabric Link and Server Topologies