Cisco DNCS System Release 2.8.1 3.8.1 4.3.1 User Guide

Page of 1878
Setting Up Stat Mux Dejitter Groups
Complete these instructions to set up SMDGs by mapping the input port that receives the multiplexed source to
the output port that modulates the source onto the network.
1.
On the DNCS Administrative Console, click the DNCS tab.
2.
On the DNCS tab, click the Network Element Provisioning tab.
3.
Click GQAM. The GQAM List window opens.
4.
Select the GQAM modulator on which you want to set up an SMDG. Then select File > Open. The Set
Up GQAM window opens with the Basic Parameters tab in the forefront.
5.
Click the Advanced Parameters tab. 
6.
Click the Set Up button for Stat Mux Dejitter Groups. The Stat Mux Dejitter Groups window opens for
the selected GQAM modulator.
7.
Click Add. Empty fields appear at the top of the window.
8.
.
Use the following fields when you manage SMDGs.
Field
Description
ID
An identifier to indicate the SMDG. This must be a numerical value
from 1 to 65535.
QAM Name
The QAM that carries this SMDG.
Bandwidth 
The bandwidth that the modulator uses:
QAM-64
QAM-256
Input Port
The input port that this SMDG uses.
Destination IP
Address
The IP address of the receiving device, based on the following
criteria:
If a GbE port receives the source, enter the IP
multicast address for the GQAM modulator.
If an ASI port receives the source, do not enter
data in this field.
Tip: When entering IP addresses, type a period to move
from octet to octet. Do 
not
 press the Tab key to move from
octet to octet; pressing the Tab key moves the cursor to
the next field on the window.
Destination UDP
Port
The UDP port of the receiving device, based on the following criteria:
If a GbE port receives the source, enter the UDP
port on the GQAM modulator that receives the multiplexed
source. 
If an ASI port receives the source, do not enter
data in this field.
Output Port
The output port that this SMDG uses.