As a further variant, if a DMP is offline when the event script starts, and then is 
reconnected, it will not receive any state changes in the future until a new event is 
started. This is because the DMP will never receive the initial Reset command that 
tells it to re-read its event script information. Therefore, when the DMP is 
reconnected, it will not be aware of the new templates and non-video playlists. 
Common Problems and Resolutions 
S ym p to m  
P o s s ib le   Ca u s e  
Ac tio n  
Script running slow or not 
running at all on the DMP. 
The DNS configuration on the 
DMP or StadiumVision Director 
is incorrect. 
Verify that DNS is disabled on the DMP. 
Verify that the DNS server (if used) is configured 
correctly in StadiumVision Director and that the 
specified DNS server is reachable. If it is not 
reachable, disable DNS on StadiumVision Director 
until the DNS server is back online. 
The Welcome screen in a luxury 
suite shows up on the wrong TV. 
The TV is configured incorrectly 
in StadiumVision. 
Determine the MAC address of the DMP either by 
looking at the DMP or by using the Menu button on the  
Cisco IR Remote to bring up the system info. Verify 
that this DM is mapped to the correct Location, and the 
Location assigned to the correct group. 
In the luxury suite, the wrong TV 
shows the concessions menu 
items. 
The configuration of the system 
was done incorrectly. 
In the luxury suite configuration, the concessions 
menu is displayed on Display #1 (or more precisely, 
Suite DMP Logical ID #1) in a room. Display #1 is 
connected to the first DMP associated with that luxury 
suite. See the StadiumVision Commerce Integration 
Design and Implementation Guide
 for more 
information.  
After pushing the script, the TV is 
not on.   
The RS-232 cable may not be 
properly connected  
Use the IR remote to turn on the TV. If you see a red 
LED flash but there is no response to the command, 
then it is likely that the RS-232 cable is plugged into 
the wrong port on the DMP. Move the connection to 
the RS-232 port on the DMP.