Cisco Cisco StadiumVision Mobile Streamer Quick Setup Guide

Page of 349
For situations where a TV cannot be controlled via RS-232 or otherwise, volume and 
mute can be controlled by the media player instead. This is behavior is indicated by 
configuring volume and mute commands that start with sigma=.
Serial Commands for RS-232 TV Control on the SV-4K 
and DMP-2K Media Players
 shows a summary of the display parameters and RS-232 commands for the 
SV-4K and DMP-2K with their default values. 
NOTE: Different TV display models might support only certain 
RS-232 commands.
Table 6.  SV-4K and DMP-2K Serial Commands
1
Command Name
Value
dmp.Input1response
62203031204F4B303878
dmp.Input2response
62203031204F4B303278
dmp.Input3response
62203031204F4B303478
dmp.Input4response
62203031204F4B303078
dmp.volumeResponseFormat
66203031204F4B5F5F78
dmp.muteOnResponse
65203031204F4B303078
dmp.monitorAPIDelay
2000
dmp.monitorAVInput
true
dmp.monitorMute
true
dmp.monitorPower
true
dmp.monitorVolume
true
dmp.displayPwrQuery
rs232.tx_hex=6B612030312046460D
dmp.displayAVInputQuery
rs232.tx_hex=6B622030312046460D
dmp.muteQuery
rs232.tx_6B652030312046460D
dmp.volumeQuery
rs232.tx_6B662030312046460D
Input1
rs232.tx_6B622030312030390D
Input2
rs232.tx_6B622030312030320D
Input3
rs232.tx_6B622030312030340D
Input4
rs232.tx_6B622030312030300D
1
The commands in this table are supported by the LG 19LH20 TV display.
34 of 331
© Cisco Systems, Inc. All rights reserved.