status is updated to match the TV.  The status log is then dispatched to SV Director 
containing the TV On/Off status. 
 
 
 
The Status Refresh from the dashboard only gets the 
DMP‟s view of the TV‟s on/off 
status and doesn‟t actually trigger the above mechanism. If the power to the TV is 
toggled without the 
DMP‟s knowledge, for example using the TV‟s IR remote, the 
results in the dashboard could take up to 5 minutes or so before it is updated. If the 
TV status is altered and the DMP is aware of the change, for example sending a TV 
on command from the Management Dashboard, this status is available immediately.  
If not already configured in the Display Specifications for the particular TV of 
interest, configure the dmp.displayPwrQuery and dmp.displayPwrOnResponse 
strings in the Display Specification screen as shown above. 
Viewing the Workflow Status 
There are indicators in the SV Director Management Dashboard, on the TV, and on 
the Control Panel that provide you information on the DMP auto provisioning status. 
Viewing the Workflow Status in the Dashboard 
Once a DMP has auto registered, you can view the auto provisioning status through 
the Management Dashboard. The Provision DMP workflow progress is displayed in