Cisco Cisco StadiumVision Mobile Streamer Maintenance Manual

Page of 94
 
 
© 2011 Cisco Systems, Inc. All rights reserved.   
 
Page 83 of 94 
Workaround 
The correct workaround depends on the Cisco switch platform that the DMP is 
connected is enhanced Power over Ethernet (ePoE) capable. 
  ePoE Capable Platforms - 
If there is ample PoE power available in the switch‟s 
power budget, apply the power inline static max 15401 interface-level 
command to each access switch port connected to a DMP-4310.   
The 
use of “power inline static max 15401” command requires “power inline port 
max 15401” be configured first.  
On an ePoE-capable switch platform, specifying a maximum power level greater 
than the 802.3af maximum of 15.4W has a side effect of causing the switch port 
to bypass the optional power class negotiation phase.   
The use of the static keyword is suggested in order to reserve the required 
power from the switch‟s power budget at configuration time.  If for some reason 
the switch‟s remaining power budget cannot accommodate the port‟s configured 
power requirement, the port is placed into error disable state at point of 
configuration, rather than point of need. 
  Non-ePoE Capable Platforms 
– Because non-ePoE capable switch platforms 
cannot be configured to deliver more than the 802.3af maximum of 15.4W/port, 
the suggested workaround is to insert a PoE splitter between the switch port and 
the DMP 4310G. Generally, a PoE splitter is used to strip the PoE power from a 
PoE-capable switch port and provide it to a non-
PoE capable device in lieu of it‟s 
usual “power brick”. In this case, the PoE splitter is used to circumvent the DMP 
4310G PoE class negotiation issue, since the PoE splitter does not attempt to 
negotiate the PoE class with the switch and simply passes through the available 
power it receives over the cable run.  
The following PoE 12V splitter has been test to operate correctly with the DMP-
4310:  
 Microsemi PD-AS-701/12  
DMP Reboot Behaviour 
If you reboot a DMP during an event script, expect the following behavior:  
  If the event is not running or the event script does not control the DMP, you will 
be brought back to full screen video of defaultVideoUrl from the registry.  
  If the DMP is controlled by the event script, then you should see the following 
behavior:  
  During the reboot, you will lose all video / templates / etc.  
  After the reboot has recovered, the DMP will take a few seconds to recover.  
  After recovery has completed, you should see the template from the script. 
(Full screen / 3 region / etc.), and the non-video playlists will be correct.